2 · Micro-Melt® Biodur® CCM Plus® is a non-magnetic, cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance.
contact2021211 · CarTech® BioDur® CCM® Alloy Page:3of9 € Poisson'sRatio€ 0.300 ModulusofElasticity(E)€ 35.0 x103 ksi ModulusofRigidity(G)€ 13.4 x103 ksi Typical
contact1 · Biodur® 108 is an essentially nickel-free austenitic stainless alloy with a high nitrogen content to maintain its austenitic structure. As a result, it has superior tensile
contact199531 · Abstract. BIO-DUR CARPENTER CCM ALLOY is a high nitrogen, low carbon wrought version of ASTM F75 cast alloy and used in the orthopedic implant
contact2 · NiTi alloys with optimized powder chemistry and print parameters exhibit superelastic and shape memory properties. none Biodur® 108 An essentially nickel-free
contact202313 · Cobalt-chrome-molybdenum CCM ASTM F1537 Alloy 1 (precision ground bars) Ltd +44 (0)1494 - Global Supplier of European
contact2023319 · BioDur® 108 is an FDA approved, essentially nickel- and cobalt-free alternative to other stainless steel options and is currently used for medical applications
contact. BioDur® Carpenter CCM® alloy is a non-magnetic cobalt-chromium-molybdenum alloy exhibiting high strength, corrosion resistance, and wear resistance. The alloy is a high
contact20211019 · Biodur® CCM® Alloy 1, Implant Quality. 인성과 연성, 내피로성, 내마모성, 높은 기계적 성질을 가지는 재료입니다. 주요 원소 Co + Cr + Mo 합금량이 98.5% 수준에
contact20211222 · Micro‐Melt® BioDur® Carpenter CCM® alloy Annealed at 1093 ⁰C/30 minutes M8 Carpenter MP35N Alloy 35 % deformed and aged at 538 ⁰C/4 h M9 Carpenter L‐605 Alloy Annealed at 1204⁰C M10 CP Titanium Grade 4 Annealed M11 Titanium Alloy Ti 6Al‐4V ELI Recrystallized
contact199551 · Abstract. BIODUR CCM PLUS ALLOY is a high carbon version of BioDur Carpenter CCM Alloy (Alloy Digest Co-96, March 1995), produced by vacuum induction melting, followed by inert gas atomization and hot isostatic pressure. Applications are in the orthopedic industry. This datasheet provides information on composition, physical
contactDuplex Alloy 255 Carpenter Alloy 925 (UNS N09925) 25Ni-20Cr-6Mo Stainless (UNS N08925 N08926) Micro-Melt® CCW Alloy BioBlu 27 Alloy Micro-Melt® CCW Plus Alloy Duplex Alloy 2205 Pyromet® Alloy 617. Medical Alloys. MP35N Alloy BioDur® 108 Alloy BioDur® Type 316LS Stainless BioDur® Carpenter CCM® Alloy BioDur® CCM Plus®
contact1 · However, as seen in Table 1, the chemistry makeup of these alloys commonly used in the industry contain a substantial amount of either nickel or cobalt. Table 1. Typical chemistries of BioDur 108, BioDur 316LS, BioDur 734, and BioDur CCM. BioDur 108 contains essentially no nickel for a patient-friendly alternative to traditionally used materials.
contact• BioDur® 108 Alloy • BioDur® 22Cr-13Ni-5Mn • Custom 455® Stainless • Custom 456® Stainless • Project 70® + Custom 630 (17Cr-4Ni) Stainless •Sandvik Bioline 316LVM (implantable) • Type 416 Stainless Cond. H (Rc 32-38) ... • ASTM F1537/F799 Alloy 2 • BioDur® Carpenter CCM® ...
contact2023319 · BioDur® 108 is an FDA approved, essentially nickel- and cobalt-free alternative to other stainless steel options and is currently used for medical applications such as implantable orthopedic devices, high-strength surgical instrumentation, and orthodontic devices. Typically, devices and instruments are produced via subtractive manufacturing ...
contactData provided by Carpenter Technology Corporation.Medical Implant Alloy. Non-magnetic Co-Cr-Mo alloy exhibiting high strength, corrosion resistance, and wear resistance. BioDur Carpenter CCM alloy..
contact20181030 · COBALT CCM ® Kobalt-Chrom-Molybdänlegierung, austenitisch, korrosionsbeständig ... Diese Kobalt-Chrom-Molybdän-Implantatlegierung ist die Carpenter-Güte MicroMelt® Biodur ... AISI/SAE/ASTM ASTM F1537 alloy 1 ISO 5832-12 Euronorm EN Sonstige UNS R31537 C Si Mn Cr Mo Ni Fe N Co max. max. max. 26.00 5.00 max. max.
contactBioDur® 316LS Stainless; BioDur® 108 Alloy; BioDur® Carpenter CCM® Alloy; BioDur® 22Cr-13Ni-5Mn-Stainless; Custom 455® Stainless; Custom 465® Stainless; Project 70® + Custom 630 (17Cr-4Ni) Stainless Sandvik Bioline 316LVM; Type 416 Stainless Cond. H (Rc 32 – 38) Type 420 Stainless; Type 440A Stainless; Type 440C Stainless; Type 17-4 PH
contact2023215 · This alloy is a powder metallurgy version of CarTech BioDur CCM alloy (ASTM F 1537 Alloy 1), which is a high nitrogen, low carbon wrought version of ASTM F 75 cast alloy. CarTech Micro-Melt BioDur Carpenter CCM alloy is produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce
contact20181030 · This alloy of Cobalt-Chromium-Molybdenum for implants is the MicroMelt® Biodur® Carpenter CCM® alloy. It meets the strictest requirements regarding biocompatibility and corrosion resistance. It is produced by powder metallurgy and has an exceptional-ly fine microstructure. It is tough, ductile, hard, as well as fatigue and wear
contactASTM F75 Cast Alloy (wrought version); ASTM F799; ASTM F1537; ISO 5832-4; ISO 5832-12, Data provided by Carpenter Technology Corporation. Medical Implant Alloy. ... Carpenter BioDur™ CCM® Medical Implant Alloy, Annealed Categories: Metal; Nonferrous Metal; Cobalt Alloy; Superalloy. Material Notes: ...
contact201151 · A few of the most commonly used materials for implants are titanium, Ti-6Al-4V, stainless steels [Carpenter’s BioDur 316LS alloy], and cobalt alloys [BioDur CCM and BioDur CCM Plus alloys],” Guitterrez notes, “and those used for instruments are typically made from other classes of stainless steel [Project 70+, Custom 630, Custom 455 ...
contact2023215 · This alloy is a powder metallurgy version of CarTech BioDur CCM alloy (ASTM F 1537 Alloy 1), which is a high nitrogen, low carbon wrought version of ASTM F 75 cast alloy. CarTech Micro-Melt BioDur Carpenter CCM alloy is produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce
contactThis page has links to all data sheets in MatWeb for the tradename BioDur™. We have several search tools, listed above, that give you more efficient methods to reach the information that you need. BioDur™ has 15 material (s) in the MatWeb database. Back to Tradename List. Carpenter BioDur™ 316LS Stainless Medical Implant Alloy, 35% Cold ...
contact20181030 · COBALT CCM ® Kobalt-Chrom-Molybdänlegierung, austenitisch, korrosionsbeständig ... Diese Kobalt-Chrom-Molybdän-Implantatlegierung ist die Carpenter-Güte MicroMelt® Biodur ... AISI/SAE/ASTM ASTM F1537 alloy 1 ISO 5832-12 Euronorm EN Sonstige UNS R31537 C Si Mn Cr Mo Ni Fe N Co max. max. max. 26.00 5.00 max. max.
contact202313 · Cobalt BC/ CCM ASTM F1537 Alloy 1; ISO 5832-12: Cobalt-Chrome-Molybdenum (CCM) is commonly used in the orthopaedic implant industry, due to its excellent biocompatibility and wear resistance. ... BioDur® 108 alloy (a product of Cartech) is an essentially nickel-free austenitic stainless alloy with high nitrogen content to maintain
contactBesides being is the most comprehensive metal properties database and knowledge source worldwide, with more than 10,000,000 property records for over 350,000 alloys, Total Materia gives you the highest quality and reliability of the only certified database of its kind in the industry. Gain access to over 450,000 alloys and their material ...
contact202285 · Translations in context of "not further worked than cold-formed" in -French from Reverso Context: Bars and rods (including wire rod) not further worked than cold-formed or cold-finished
contactBioDur™ Carpenter CCM® Medical Implant Alloy, Hot Worked; BioDur™ Carpenter CCM® Medical Implant Alloy, Warm Worked; BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 1 hr; BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1093°C 2 hr; BioDur™ CCM Plus™ Medical Implant Alloy, Annealed 1121°C 1 hr; BioDur™ CCM Plus ...
contact20211215 · M5 BioDur® Carpenter . CCM® Alloy Annealed . M6 BioDur® CCM Plus® Alloy . Annealed at . 1093 ⁰ C/1 h . M7 Micro ‐ Melt® BioDur® Carpenter CCM® alloy . Annealed at . 1093 .
contact20181030 · This alloy of Cobalt-Chromium-Molybdenum for implants is the MicroMelt® Biodur® Carpenter CCM® alloy. It meets the strictest requirements regarding biocompatibility and corrosion resistance. It is produced by powder metallurgy and has an exceptional-ly fine microstructure. It is tough, ductile, hard, as well as fatigue and wear
contact202323 · This alloy is a high carbon version of CarTech BioDur CCM alloy and meets the requirements of ASTM F1537, ASTM F799, ISO 5832-12 and ISO 5832-4. CarTech BioDur CCM Plus alloy is a wrought powder metallurgy product produced by vacuum induction melting (VIM) followed by gas atomization and hot isostatic pressing to produce
contact201151 · A few of the most commonly used materials for implants are titanium, Ti-6Al-4V, stainless steels [Carpenter’s BioDur 316LS alloy], and cobalt alloys [BioDur CCM and BioDur CCM Plus alloys],” Guitterrez notes, “and those used for instruments are typically made from other classes of stainless steel [Project 70+, Custom 630, Custom 455 ...
contact202313 · Cobalt BC/ CCM ASTM F1537 Alloy 1; ISO 5832-12: Cobalt-Chrome-Molybdenum (CCM) is commonly used in the orthopaedic implant industry, due to its excellent biocompatibility and wear resistance. ... BioDur® 108 alloy (a product of Cartech) is an essentially nickel-free austenitic stainless alloy with high nitrogen content to maintain
contactThis page has links to all data sheets in MatWeb for the tradename BioDur™. We have several search tools, listed above, that give you more efficient methods to reach the information that you need. BioDur™ has 15 material (s) in the MatWeb database. Back to Tradename List. Carpenter BioDur™ 316LS Stainless Medical Implant Alloy, 35% Cold ...
contactData provided by Carpenter Technology Corporation.Medical Implant Alloy. Non-magnetic Co-Cr-Mo alloy exhibiting high strength, corrosion resistance, and wear resistance. BioDur Carpenter CCM alloy..
contact202025 · cobalt-based alloy developed at 1223 K with 8 h of exposure showed the best wear behavior (0.64 mg km 1) in comparison with the other borided samples, as well as with the reference material (cobalt-based alloy). Otherwise, the sliding wear behavior of cobalt boride layers (CoB-Co 2B) formed on the surface of the ASTM F1537 alloy
contact1 · 319-42-40. E-mail: . Екатеринбург, ул. ENG. RU. Main; Store; Manufacturing; Contacts
contactBiodur® 108. Le Biodur® 108 est un acier inoxydable austénitique pratiquement sans nickel dont la plupart des propriétés sont identiques à celles des autres aciers inoxydables, y compris la forte résistance à la corrosion du 316LVM et une résistance similaire à celle de l'acier inoxydable 304 recuit à l'état de ressort.
contact